Load import formats

Which reaction tables the importer reads, and how it turns reactions into foundation loads.

Recognised sources
SourceTable
ETABS, SAFE, SAP2000 (CSI)“Joint Reactions” or “Support Reactions” exported to Excel or CSV; CSI key=value text
STAAD.ProSupport Reactions (CSV or XLSX), with an optional .std for coordinates and load types
CivilTech templateA CSV with a P column

Accepted files are .xlsx, .xlsm, .csv, .txt and .tsv. Legacy .xls is rejected, and so are member-force tables.

Sign and axis convention

The engine works with the load the column puts on the foundation: P downward and compression-positive, Mx moving the resultant along +x (the footing length L, so ex = Mx / P), My moving it along +y (the width B). A reaction is the support’s force on the structure, so the importer negates it:

Reaction to foundation load
SoftwareVerticalPMxMyHxHy
CSI (ETABS, SAFE, SAP2000)Z upFZ−MYMX−FX−FY
STAADY upFYMZMX−FXFZ

If at least 80 % of the non-zero dead and live P values are negative, the file holds loads on supports rather than reactions; every component is negated and you are warned. Units come from a units row, the header (FZ (kN)) or your override; forces in kN, N, MN, kip, lb, kgf and tonf are recognised. The output is always kN, kN·m and mm.

Something missing or wrong? Tell us from the changelog page or the feedback button.