Basement Design
Basement walls and base slabs, with earth pressure, buoyancy and waterproofing checks.
IS 456 + IS 3370, ACI 318, EC2
Open Basement DesignOpen it at /civiltechstudio/basement-design/app. Status: live.
Design a single-level propped basement to IS 456 and IS 3370: 3.5 m deep, 15 × 10 m in plan, with the water table 2.0 m below ground.
- Under Design Code, select
IS 456. - In the Geometry step, enter Basement Depth (to underside of base slab)
3.5m, Plan Length15m and Plan Width10m. Keep Wall Thickness at300mm and Base Slab at400mm. - Go to the Soil & loads step, expand Soil & Loading and set Water Table to
2.0m. Keep SBC at200kN/m², γ soil at18and φ (friction) at30. - Go to the Materials step, expand Materials, and confirm that Wall Support is set to
Proppedand Water-Retaining is ticked. - Select Design, then select the Results tab.
- IS 456 with IS 3370 crack-width limits
- ACI 318
- Eurocode 2
- Basement depth (ground level to the underside of the base slab — add the slab thickness to a floor depth), plan length and width, wall and slab thicknesses.
- Wall support: Propped (by the slab above) or Cantilever.
- SBC, soil properties and water table; surcharge.
- Wall and base-slab moments and steel, crack width, uplift factor of safety.
- Exports: design calculation PDF, vector PDF, Excel, DXF, JSON.
- Waterproofing is checked as crack-width control on the concrete; membranes are drawn, not designed.