Design basis: loads, combinations and soil

What you enter, what the engine generates from it, and the conventions it holds to.

You enter unfactored load cases at the top of the footing. The engine builds the code’s combinations from them in three families, because soil, concrete and stability are checked at different load levels:

Combination families
FamilyUsed forLoad level
ServiceSoil bearingUnfactored, per the code’s service rules
StrengthConcrete: bending, shear, punching, anchorageFactored
StabilityOverturning, sliding, upliftFavourable dead load factored down — for example 0.9D under IS 456 cl. 20

Wind acts one case at a time, in both senses. Earthquake in X and Y is combined 100 / 30. Your own combinations are designed for alongside the code’s, never instead of them.

Bearing capacity: net or gross

Most soil reports quote a net safe bearing capacity — the pressure the soil can take above what the excavated ground already applied. Presumed values from tables are often gross. Tell the design basis which one you have, so the bearing check compares like with like. The Geotechnical module reports net SBC, and its hand-off to Foundation Design carries the basis with it.

One moment convention

Throughout the studio, Mx moves the load along X: the eccentricity ex = Mx / P is measured against the footing length L, and My moves it along Y against the width B. The load importer converts ETABS, SAFE, SAP2000 and STAAD reactions to this convention, so the same physical reaction gives the same loads whichever program it came from.

Units

Inputs are metric. Modules with a unit toggle display Imperial values, and reports offer an Export units choice of SI or Imperial.

Something missing or wrong? Tell us from the changelog page or the feedback button.