CivilTech Studio
PricingBlog
CivilTech Studio
PricingBlog

CivilTech Studio blog

Posts tagged #homeowners

Plain-language guides for people building a house: septic tanks, rainwater harvesting, building bye-laws and cost estimates.

Write a post
Concrete StructuresGeotechnical & FoundationsWater & EnvironmentSite, Loads & QACompliance & Approvals
All#is-456#site-engineering#rcc#bbs#reinforcement#rcc-design
More tags
#quantity-estimation#detailing#punching-shear#structural-analysis#is-3370#retaining-wall#quality-control#foundation-design#geotechnical
Sort:LatestMost readQuick reads2 posts
Cover image for Rainwater Harvesting Pit Design (IS 15797) — Example

#rainwater-harvesting#recharge-pit#cgwb

Rainwater Harvesting Pit Design (IS 15797) — Example

Rainwater harvesting pit design step by step: annual harvest, rational-method storm inflow, recharge pit size from filter porosity and soil infiltration, and the 24-hour drain-down check, with a 150 m² roof worked example.

15 Oct 202612 min read

Cover image for Septic Tank Design (IS 2470) — Size & Dimensions

#is-2470

Share your site experience

Write about a design problem you solved or a lesson from site. We review every post and publish the ones we approve.

Write a post
CivilTech Studio
ModulesFree toolsPricingDocsBlogWhat's newTermsPrivacy
Built for structural engineers
#homeowners
#septic-tank
#sanitation

Septic Tank Design (IS 2470) — Size & Dimensions

Septic tank design calculation as per IS 2470 (Part 1): sewage flow, detention, digestion and sludge volumes, Table 5/6 minimum sizes and L × B × depth, worked through for a 10-user house with a size table for 5 to 150 users.

15 Oct 202612 min read