Rebar Calculator

Bars for a slab, or steel area and spacing — metric or US

Units
Stock bars to order
28 × 12 m bars
335.2 m total · 297.6 kg (0.298 t)
Bar layout
Bars along the length
27 × 5.9 m
Bars along the width
41 × 3.9 m
Total incl. 5% waste
335.2 m

Bars per direction = floor(clear span ÷ spacing) + 1, with the clear span = slab size − 2 × edge cover. Stock count assumes offcuts are not reused.

How the Rebar Calculator works

The Bars for a slab mode answers how much rebar a rectangular slab needs. Enter the slab length and width, bar size, spacing and edge cover, in metric or US units (#3 to #11 bars). Bars each way = floor((slab size − 2 × cover) ÷ spacing) + 1; each run is the slab size less the cover, plus a lap wherever it is longer than one stock bar. The total length, with waste, gives the number of stock bars to order and the weight.

Slab and wall reinforcement is specified as a bar size at a spacing, for example 10 mm bars at 150 mm centres. Design, though, gives you a required area of steel per metre width (Ast, mm²/m). This calculator converts between the two in either direction.

The area of one bar is π·φ²/4. In a one-metre strip there are 1000/s bars, so the steel provided per metre is the bar area multiplied by 1000/s. Going the other way, the exact spacing for a required Ast is bar area × 1000 / Ast; the calculator rounds it down to the nearest 5 mm so the steel provided is never less than required.

The spacing is then checked against IS 456 Cl 26.3.3(b): main bars in slabs may not be spaced wider than 3d or 300 mm, whichever is less, and distribution bars not wider than 5d or 450 mm. Enter the effective depth d to apply the 3d / 5d limit; without it only the absolute limit is checked.

Area of one bar
a = π·φ² / 4
Steel per metre width
Ast = a × 1000 / s
Spacing for a required Ast
s = a × 1000 / Ast
Max spacing, main bars (slab)
s ≤ min(3d, 300 mm)
Max spacing, distribution bars
s ≤ min(5d, 450 mm)

Follows: IS 456:2000 Cl 26.3.3(b)

Worked example: spacing of 10 mm main bars for Ast = 450 mm²/m

Given

  • Required area of steel: 450 mm²/m (main bars in a slab)
  • Bar diameter φ = 10 mm
  • Effective depth d = 125 mm

Steps

  1. Area of one 10 mm bar: a = π × 10² / 4 = 78.54 mm².
  2. Exact spacing: s = 78.54 × 1000 / 450 = 174.5 mm.
  3. Round down to the nearest 5 mm: s = 170 mm.
  4. Steel provided: 78.54 × 1000 / 170 = 462 mm²/m, which is at least the 450 mm²/m required.
  5. Maximum spacing for main bars: min(3 × 125, 300) = min(375, 300) = 300 mm. 170 mm is within it.

Result: 10 mm bars at 170 mm c/c, providing 462 mm²/m.

Enter the same values in the calculator above to check each step.

Frequently asked questions

How many rebar do I need for a slab?

Count the bars each way: take the slab dimension less twice the edge cover, divide by the spacing, round down and add one. A 20 × 20 ft slab with #4 bars at 12 in and 3 in cover needs 20 bars each way, each 19.5 ft long: 780 ft in one mat, or 39 bars of 20 ft (521 lb) before laps and waste.

How do I calculate the area of steel per metre for a given bar spacing?

Find the area of one bar (π·φ²/4) and multiply it by the number of bars in one metre, which is 1000 divided by the spacing in millimetres. For example, 12 mm bars at 150 mm centres give 113.1 × 1000 / 150 = 754 mm² per metre.

What is the maximum spacing of reinforcement in a slab as per IS 456?

IS 456 Cl 26.3.3(b) limits main bars to 3 times the effective depth or 300 mm, whichever is smaller, and distribution bars to 5 times the effective depth or 450 mm, whichever is smaller.

Why is the calculated spacing rounded down and not to the nearest value?

Rounding up would put the bars further apart and provide less steel than the design requires. Rounding down to a practical 5 mm step keeps the steel provided at or above the required area.

Can I use this for wall and footing reinforcement too?

Yes. The area-per-metre conversion works for any bar mesh. The automatic maximum-spacing check applies the IS 456 slab rule, so for walls and footings check the spacing limit that applies to that member separately.

Does the calculator check minimum spacing or cover?

No. It converts between spacing and area and checks the maximum spacing only. Minimum clear spacing between bars, cover and the minimum reinforcement percentage still need to be checked in your design.

Step-by-step guides